Loading...
Thumbnail Image
Non-discoverable
Item

Cryogenic Characterization of FBK RGB-HD SiPMs

Aalseth, CE
Acerbi, F
Agnes, P
Albuquerque, IFM
Alexander, T
Alici, A
Alton, AK
Ampudia, P
Antonioli, P
Arcelli, S
... show 10 more
Research Projects
Organizational Units
Journal Issue
DOI
10.1088/1748-0221/12/09/P09030
Abstract
© 2017 IOP Publishing Ltd and Sissa Medialab. We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A cryogenic setup was used to operate the SiPMs at varying temperatures and a custom data acquisition system and analysis software were used to precisely characterize the primary dark noise, the correlated noise, and the gain of the devices. We demonstrate that FBK RGB-HD SiPMs with low quenching resistance (RGB-HD-LRq) can be operated from 40 K to 300 K with gains in the range 105 to 106 and noise rates at a level of around 1 Hz/mm2.