Real-time feedback of air quality in children’s bedrooms reduces exposure to secondhand smoke
dc.creator | Berardi, Vincent | |
dc.creator | Collins, Bradley N. | |
dc.creator | Glynn, Laura M. | |
dc.creator | Lepore, Stephen | |
dc.creator | Mahabee-Gittens, E. Melinda | |
dc.creator | Wilson, Karen M | |
dc.creator | Hovell, Melbourne F. | |
dc.date.accessioned | 2024-03-11T19:20:36Z | |
dc.date.available | 2024-03-11T19:20:36Z | |
dc.date.issued | 2022-06-22 | |
dc.identifier.citation | Berardi V, Collins BN, Glynn LM, et al. Real-time feedback of air quality in children’s bedrooms reduces exposure to secondhand smoke. Tobacco Prevention & Cessation. 2022;8(June):23. doi:10.18332/tpc/149908. | |
dc.identifier.issn | 2459-3087 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12613/9758 | |
dc.description.abstract | Introduction: Secondhand smoke (SHS) exposure creates health risks for nonsmokers and is especially detrimental to children. This study evaluated whether immediate feedback in response to poor indoor air quality in children’s bedrooms can reduce the potential for SHS exposure, as measured by adherence to a World Health Organization (WHO) indoor air standard. Methods: Homes that contained children and an adult who regularly smoked inside (n=298) had an air particle monitor installed in the child’s bedroom. These devices measured the concentration of particulate matter (PM2.5) for approximately three months and, for half of the participants, immediately provided aversive feedback in response to elevated PM2.5. Hierarchical linear models were fit to the data to assess whether the intervention increased the probability that: 1) a given day was below the WHO guideline for daily exposure, and 2) a household established and maintained a smoke-free home (SFH), operationalized as achieving 30 consecutive days below the WHO guideline. The intervention’s impact was calculated as groupby- time effects. Results: The likelihood that a child’s bedroom met the WHO indoor air quality standard on a given day increased such that the baseline versus post-baseline odds ratio (OR) of maintaining indoor PM2.5 levels below the WHO guideline was 2.38 times larger for participants who received the intervention. Similarly, the baseline versus post-baseline OR associated with achieving an SFH was 3.49 times larger for participants in the intervention group. Conclusions: The real-time intervention successfully drove clinically meaningful changes in smoking behavior that mitigated indoor PM2.5 levels in children’s bedrooms and thereby reduced SHS exposure. These results demonstrate the effectiveness of targeting sensitive microenvironments by giving caregivers actionable information about children’s SHS risks. Future extensions should examine additional microenvironments and focus on identifying the potential for SHS exposure before it occurs. | |
dc.format.extent | 5 pages | |
dc.language | English | |
dc.language.iso | eng | |
dc.relation.ispartof | Faculty/ Researcher Works | |
dc.relation.haspart | Tobacco Prevention & Cessation, Vol. 8 | |
dc.relation.isreferencedby | EU European Publishing | |
dc.rights | Attribution CC BY | |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Secondhand smoke | |
dc.subject | Air quality | |
dc.subject | Youth | |
dc.subject | Air monitoring | |
dc.subject | Smoke-free environments | |
dc.subject | In-home smoking | |
dc.title | Real-time feedback of air quality in children’s bedrooms reduces exposure to secondhand smoke | |
dc.type | Text | |
dc.type.genre | Journal article | |
dc.description.department | Social and Behavioral Sciences | |
dc.relation.doi | http://dx.doi.org/10.18332/tpc/149908 | |
dc.ada.note | For Americans with Disabilities Act (ADA) accommodation, including help with reading this content, please contact scholarshare@temple.edu | |
dc.description.schoolcollege | Temple University. College of Public Health | |
dc.creator.orcid | Lepore|0000-0001-7370-6280 | |
dc.temple.creator | Collins, Bradley N. | |
dc.temple.creator | Lepore, Stephen J. | |
refterms.dateFOA | 2024-03-11T19:20:36Z |