Genre
Journal ArticleDate
2017-09-26Author
Aalseth, CEAcerbi, F
Agnes, P
Albuquerque, IFM
Alexander, T
Alici, A
Alton, AK
Ampudia, P
Antonioli, P
Arcelli, S
Ardito, R
Arnquist, IJ
Asner, DM
Back, HO
Batignani, G
Bertoldo, E
Bettarini, S
Bisogni, MG
Bocci, V
Bondar, A
Bonfini, G
Bonivento, W
Bossa, M
Bottino, B
Bunker, R
Bussino, S
Buzulutskov, A
Cadeddu, M
Cadoni, M
Caminata, A
Canci, N
Candela, A
Cantini, C
Caravati, M
Cariello, M
Carlini, M
Carpinelli, M
Castellani, A
Catalanotti, S
Cataudella, V
Cavalcante, P
Cereseto, R
Chen, Y
Chepurnov, A
Chiavassa, A
Cicalò, C
Cifarelli, L
Citterio, M
Cocco, AG
Colocci, M
Corgiolu, S
Covone, G
Crivelli, P
D'Antone, I
D'Incecco, M
Rolo, MDDR
Daniel, M
Davini, S
Candia, AD
Cecco, SD
Deo, MD
Filippis, GD
De Guido, G
Rosa, GD
Dellacasa, G
Demontis, P
Derbin, AV
Devoto, A
Eusanio, FD
Pietro, GD
Dionisi, C
Dolgov, A
Dormia, I
Dussoni, S
Empl, A
Ferri, A
Filip, C
Fiorillo, G
Fomenko, K
Franco, D
Froudakis, GE
Gabriele, F
Gabrieli, A
Galbiati, C
Abia, PG
Gendotti, A
Ghisi, A
Giagu, S
Gibertoni, G
Giganti, C
Giorgi, M
Giovanetti, GK
Gligan, ML
Gola, A
Gorchakov, O
Goretti, AM
Granato, F
Grassi, M
Grate, JW
Grigoriev, GY
Subject
Cryogenic detectorsPhoton detectors for UV
visible and IR photons (solid-state)
Photon detectors forUV
visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs ,etc)
Permanent link to this record
http://hdl.handle.net/20.500.12613/5673
Metadata
Show full item recordDOI
10.1088/1748-0221/12/09/P09030Abstract
© 2017 IOP Publishing Ltd and Sissa Medialab. We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A cryogenic setup was used to operate the SiPMs at varying temperatures and a custom data acquisition system and analysis software were used to precisely characterize the primary dark noise, the correlated noise, and the gain of the devices. We demonstrate that FBK RGB-HD SiPMs with low quenching resistance (RGB-HD-LRq) can be operated from 40 K to 300 K with gains in the range 105 to 106 and noise rates at a level of around 1 Hz/mm2.Citation to related work
IOP PublishingHas part
Journal of InstrumentationADA compliance
For Americans with Disabilities Act (ADA) accommodation, including help with reading this content, please contact scholarshare@temple.eduae974a485f413a2113503eed53cd6c53
http://dx.doi.org/10.34944/dspace/5655