Show simple item record

dc.creatorSharma, SD
dc.creatorKumar, S
dc.creatorSrinivasan, P
dc.creatorChourasiya, G
dc.date.accessioned2021-01-31T23:48:09Z
dc.date.available2021-01-31T23:48:09Z
dc.date.issued2011-01-01
dc.identifier.issn1526-9914
dc.identifier.issn1526-9914
dc.identifier.doihttp://dx.doi.org/10.34944/dspace/5509
dc.identifier.other22089009 (pubmed)
dc.identifier.urihttp://hdl.handle.net/20.500.12613/5527
dc.description.abstractA guarded cylindrical graphite ionization chamber of nominal volume 1000 cm3 was designed and fabricated for use as a reference standard for low-dose rate 137Cs brachytherapy sources. The air kerma calibration coefficient (NK) of this ionization chamber was estimated analytically using Burlin's general cavity theory, as well as by the Monte Carlo simulation and validated experimentally using Amersham CDCS-J-type 137Cs reference source. In the analytical method, the NK was calculated for 662 keV gamma rays of 137Cs brachytherapy source. In the Monte Carlo method, the geometry of the measurement setup and physics-related input data of the 137Cs source and the surrounding material were simulated using the Monte Carlo N-Particle code. The photon energy fluence was used to arrive at the reference air kerma rate (RAKR) using mass energy absorption coefficient. The energy deposition rates were used to simulate the value of charge rate in the ionization chamber, and the NK was determined. The analytical and Monte Carlo values of NK of the cylindrical graphite ionization chamber for 137Cs brachytherapy source are in agreement within 1.07%. The deviation of analytical and Monte Carlo values from experimental values of NK is 0.36% and 0.72%, respectively. This agreement validates the analytical value, and establishes this chamber as a reference standard for RAKR or AKS measurement of 137Cs brachytherapy sources.
dc.format.extent275-285
dc.language.isoen
dc.relation.haspartJournal of Applied Clinical Medical Physics
dc.relation.isreferencedbyWiley
dc.rightsCC BY
dc.subjectBrachytherapy
dc.subjectCesium Radioisotopes
dc.subjectGraphite
dc.subjectMonte Carlo Method
dc.subjectPhotons
dc.subjectRadiotherapy Dosage
dc.subjectReference Standards
dc.titleEstablishment of air kerma reference standard for low dose rate Cs-137 brachytherapy sources
dc.typeArticle
dc.type.genreJournal Article
dc.relation.doi10.1120/jacmp.v12i4.3553
dc.ada.noteFor Americans with Disabilities Act (ADA) accommodation, including help with reading this content, please contact scholarshare@temple.edu
dc.creator.orcidKumar, Sudhir|0000-0002-9918-8212
dc.date.updated2021-01-31T23:48:05Z
refterms.dateFOA2021-01-31T23:48:09Z


Files in this item

Thumbnail
Name:
Establishment of air kerma ...
Size:
841.4Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record