dc.description.abstract© 2014 Fahimian et al.; Background: Gated Volumetric Modulated Arc Therapy (VMAT) is an emerging radiation therapy modality for treatment of tumors affected by respiratory motion. However, gating significantly prolongs the treatment time, as delivery is only activated during a single respiratory phase. To enhance the efficiency of gated VMAT delivery, a novel dual-gated VMAT (DG-VMAT) technique, in which delivery is executed at both exhale and inhale phases in a given arc rotation, is developed and experimentally evaluated. Methods: Arc delivery at two phases is realized by sequentially interleaving control points consisting of MUs, MLC sequences, and angles of VMAT plans generated at the exhale and inhale phases. Dual-gated delivery is initiated when a respiration gating signal enters the exhale window; when the exhale delivery concludes, the beam turns off and the gantry rolls back to the starting position for the inhale window. The process is then repeated until both inhale and exhale arcs are fully delivered. DG-VMAT plan delivery accuracy was assessed using a pinpoint chamber and diode array phantom undergoing programmed motion. Results: DG-VMAT delivery was experimentally implemented through custom XML scripting in Varian’s TrueBeam™ STx Developer Mode. Relative to single gated delivery at exhale, the treatment time was improved by 95.5% for a sinusoidal breathing pattern. The pinpoint chamber dose measurement agreed with the calculated dose within 0.7%. For the DG-VMAT delivery, 97.5% of the diode array measurements passed the 3%/3 mm gamma criterion. Conclusions: The feasibility of DG-VMAT delivery scheme has been experimentally demonstrated for the first time. By leveraging the stability and natural pauses that occur at end-inspiration and end-exhalation, DG-VMAT provides a practical method for enhancing gated delivery efficiency by up to a factor of two.
dc.format.extent209-209
dc.language.isoen
dc.relation.haspartRadiation Oncology
dc.relation.isreferencedbySpringer Science and Business Media LLC
dc.rightsCC BY
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/
dc.subjectDual gating
dc.subjectIGRT
dc.subjectVMAT
dc.subjectSBRT
dc.titleDual-gated volumetric modulated arc therapy
dc.typeArticle
dc.type.genreJournal Article
dc.relation.doi10.1186/1748-717X-9-209
dc.ada.noteFor Americans with Disabilities Act (ADA) accommodation, including help with reading this content, please contact scholarshare@temple.edu
dc.creator.orcidWu, Huanmei|0000-0003-0346-6044
dc.date.updated2021-01-31T16:47:27Z
refterms.dateFOA2021-01-31T16:47:32Z


Files in this item

Thumbnail
Name:
Dual-Gated Volumetric Modulated ...
Size:
2.375Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record

CC BY
Except where otherwise noted, this item's license is described as CC BY