Human perception of electrical stimulation on the surface of somatosensory cortex
Genre
Journal ArticleDate
2017-05-01Author
Hiremath, SVTyler-Kabara, EC
Wheeler, JJ
Moran, DW
Gaunt, RA
Collinger, JL
Foldes, ST
Weber, DJ
Chen, W
Boninger, ML
Wang, W
Subject
Brain MappingBrain-Computer Interfaces
Electric Stimulation
Electrodes
Electrodes, Implanted
Humans
Somatosensory Cortex
Permanent link to this record
http://hdl.handle.net/20.500.12613/4905
Metadata
Show full item recordDOI
10.1371/journal.pone.0176020Abstract
Recent advancement in electrocorticography (ECoG)-based brain-computer interface technology has sparked a new interest in providing somatosensory feedback using ECoG electrodes, i.e., cortical surface electrodes. We conducted a 28-day study of cortical surface stimulation in an individual with arm paralysis due to brachial plexus injury to examine the sensation produced by electrical stimulation of the somatosensory cortex. A high-density ECoG grid was implanted over the somatosensory and motor cortices. Stimulation through cortical surface electrodes over the somatosensory cortex successfully elicited arm and hand sensations in our participant with chronic paralysis. There were three key findings. First, the intensity of perceived sensation increased monotonically with both pulse amplitude and pulse frequency. Second, changing pulse width changed the type of sensation based on qualitative description provided by the human participant. Third, the participant could distinguish between stimulation applied to two neighboring cortical surface electrodes, 4.5 mm center-to-center distance, for three out of seven electrode pairs tested. Taken together, we found that it was possible to modulate sensation intensity, sensation type, and evoke sensations across a range of locations from the fingers to the upper arm using different stimulation electrodes even in an individual with chronic impairment of somatosensory function. These three features are essential to provide effective somatosensory feedback for neuroprosthetic applications.Citation to related work
Public Library of Science (PLoS)Has part
PLoS ONEADA compliance
For Americans with Disabilities Act (ADA) accommodation, including help with reading this content, please contact scholarshare@temple.eduae974a485f413a2113503eed53cd6c53
http://dx.doi.org/10.34944/dspace/4887
Scopus Count
Collections
Except where otherwise noted, this item's license is described as https://creativecommons.org/publicdomain/zero/1.0/