Performance of a segmented 6Li-loaded liquid scintillator detector for the PROSPECT experiment
Genre
Pre-printDate
2018-06-29Author
Ashenfelter, JBalantekin, AB
Band, HR
Bass, CD
Bergeron, DE
Berish, D
Bowden, NS
Brodsky, JP
Bryan, CD
Telles, AB
Cherwinka, JJ
Classen, T
Commeford, K
Conant, A
Davee, D
Deichert, G
Diwan, MV
Dolinski, MJ
Erickson, A
Foust, BT
Gaison, JK
Galindo-Uribarri, A
Gilje, K
Hackett, B
Han, K
Hans, S
Hansell, A
Heeger, KM
Heffron, B
Insler, J
Jaffe, DE
Jones, D
Kyzylova, O
Lane, CE
Langford, TJ
Larosa, J
Littlejohn, BR
Lopez, F
Caicedo, DAM
Matta, J
McKeown, RD
Mendenhall, MP
Minock, J
Mueller, PE
Mumm, HP
Napolitano, J
Neilson, R
Nikkel, JA
Norcini, D
Nour, S
Pushin, DA
Qian, X
Romero-Romero, E
Rosero, R
Surukuchi, PT
Trinh, C
Tyra, MA
Wagner, JM
White, C
Wilhelmi, J
Wise, T
Yeh, M
Yen, YR
Zhang, A
Zhang, C
Zhang, X
Subject
Liquid detectorsNeutrino detectors
Neutron detectors (cold, thermal, fast neutrons)
Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators)
Permanent link to this record
http://hdl.handle.net/20.500.12613/4622
Metadata
Show full item recordDOI
10.1088/1748-0221/13/06/P06023Abstract
© 2018 IOP Publishing Ltd and Sissa Medialab. This paper describes the design and performance of a 50 liter, two-segment 6Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850±20 PE/MeV, an energy resolution of σ = 4.0±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85±3 cm is measured in each segment. The 0.1% by mass concentration of 6Li in the scintillator results in a measured neutron capture time of τ = 42.8±0.2 μs. The long-term stability of the scintillator is also discussed. The detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.Citation to related work
IOP PublishingHas part
Journal of InstrumentationADA compliance
For Americans with Disabilities Act (ADA) accommodation, including help with reading this content, please contact scholarshare@temple.eduae974a485f413a2113503eed53cd6c53
http://dx.doi.org/10.34944/dspace/4604