Show simple item record

dc.contributor.advisorPatil, Chetan Appasaheb
dc.creatorSun, Yu
dc.date.accessioned2020-11-03T15:33:54Z
dc.date.available2020-11-03T15:33:54Z
dc.date.issued2017
dc.identifier.urihttp://hdl.handle.net/20.500.12613/2483
dc.description.abstractRaman spectroscopy is an effective optical analysis of the biochemically specific characterization of tissues without contrast agents or exogenous dyes. Applications of Raman spectroscopy include analysis and biomarker investigation, disease diagnosis and surgical guidance. One major challenge in Raman spectroscopy is removing inherent fluorescence background present in samples to acquire Raman signatures. In some tissues, like liver, kidney and darkly pigment skin, the auto-fluorescence background is strong enough to overwhelm the Raman peaks in conventional Near-Infrared (NIR) Raman systems. Recent publications have shown that using Raman systems with excitation sources with wavelengths beyond 830 nm and short-wave infrared (SWIR) InGaAs Array detectors resulted in dramatically reduced auto-fluorescence. The unique characteristics of Raman signals collected from SWIR systems versus NIR Raman systems requires inspection of the suitability of spectral pre-processing techniques. This thesis focused on the development of spectral processing techniques at three different steps; 1) detector background & noise reduction; 2) Auto-fluorescence background subtraction; 3) detection of outlier measurements to assist statistical classification. Detector background and noise reduction was compared between two different techniques, and a direct subtraction method resulted in better performance to reduce fixed pattern noise unique to InGaAs arrays. For the aim 2, three different algorithms for fluorescence background removal were developed, and a modified polynomial fitting method was found to be most appropriate for the low signal-to-noise (SNR) spectra. Finally, local outlier factor(LOF), a multivariate statistical outlier metric, was implemented in a two-stage fashion, and shown to be effective at identifying raw measurement errors and Raman spectra outliers. The overall outcome of this thesis was the evaluation of spectral processing techniques for SWIR Raman spectroscopy systems, and the development of specific techniques to optimize data quality and best prepare spectra for statistical analysis.
dc.format.extent56 pages
dc.language.isoeng
dc.publisherTemple University. Libraries
dc.relation.ispartofTheses and Dissertations
dc.rightsIN COPYRIGHT- This Rights Statement can be used for an Item that is in copyright. Using this statement implies that the organization making this Item available has determined that the Item is in copyright and either is the rights-holder, has obtained permission from the rights-holder(s) to make their Work(s) available, or makes the Item available under an exception or limitation to copyright (including Fair Use) that entitles it to make the Item available.
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectEngineering, Biomedical
dc.subjectAuto-fluorescence Background Subtraction
dc.subjectIngaas Detector
dc.subjectNoise Reduction
dc.subjectOutlier Detection
dc.subjectRaman Spectroscopy
dc.titleSIGNAL PROCESSING FOR SHORT WAVE INFRARED (SWIR) RAMAN SPECTROSCOPY DIAGNOSIS OF CANCER
dc.typeText
dc.type.genreThesis/Dissertation
dc.contributor.committeememberSpence, Andrew J.
dc.contributor.committeememberPleshko, Nancy
dc.description.departmentBioengineering
dc.relation.doihttp://dx.doi.org/10.34944/dspace/2465
dc.ada.noteFor Americans with Disabilities Act (ADA) accommodation, including help with reading this content, please contact scholarshare@temple.edu
dc.description.degreeM.S.
refterms.dateFOA2020-11-03T15:33:54Z


Files in this item

Thumbnail
Name:
Sun_temple_0225M_12843.pdf
Size:
5.657Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record