• Login
    View Item 
    •   Home
    • Theses and Dissertations
    • Theses and Dissertations
    • View Item
    •   Home
    • Theses and Dissertations
    • Theses and Dissertations
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of TUScholarShareCommunitiesDateAuthorsTitlesSubjectsGenresThis CollectionDateAuthorsTitlesSubjectsGenres

    My Account

    LoginRegister

    Help

    AboutPeoplePoliciesHelp for DepositorsData DepositFAQs

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    OPTIMIZATION AND APPLICATION OF PHOTOLUMINESCENCE- FOLLOWING ELECTRON-TRANSFER WITH TRIS(TETRAMETHYL- 1,10-PHENANTHROLINE) Os/Ru(III) COMPLEXES AND FENTON BASED CHEMILUMINESCENCE DETECTION OF NSAIDS AND DOPAMINE IN BIOLOGICAL SAMPLES

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    Patel_temple_0225E_12484.pdf
    Size:
    6.366Mb
    Format:
    PDF
    Download
    Genre
    Thesis/Dissertation
    Date
    2016
    Author
    Patel, Mohit Pratish
    Advisor
    Jansen Varnum, Susan
    Committee member
    Wunder, Stephanie L.
    Zdilla, Michael J., 1978-
    Cannon, Kevin C.
    Department
    Chemistry
    Subject
    Chemistry
    Chemistry, Analytical
    Inorganic Chemistry
    Chemiluminescence
    Complex
    Electron Transfer
    Luminescence
    Osmium
    Ruthenium
    Permanent link to this record
    http://hdl.handle.net/20.500.12613/2112
    
    Metadata
    Show full item record
    DOI
    http://dx.doi.org/10.34944/dspace/2094
    Abstract
    Biogenic monoamines such as dopamine play an important role as major neurotransmitters. Simultaneous determination of the concentration changes is thus crucial to understand brain function. Additionally, quantification of pharmaceutically active compounds (PhACs) and their metabolites in biological fluids is an important issue for forensic tests, clinical toxicology and pharmaceutical analysis. We have developed two postcolumn luminescence detection methods coupled to a 2-dimensional-solid phase extraction (2D-SPE) system. The postcolumn reaction methods used in this study are the redox-dependent photoluminescence-following electron-transfer (PFET) and Fenton-based chemiluminescence techniques, for the determination of certain neurotransmitter and nonsteroidal anti-inflammatory drugs (NSAIDs). A stable [Os(tmphen)3]3+ (tmphen = 3,4,7,8-tetramethyl-1,10-phenanthroline) reagent was prepared in neutral aqueous solution by oxidation of [Os(tmphen)3]2+ with lead(IV) oxide. [Os(tmphen)3]2+ and [Os(tmphen)3]3+ are characterized by absorption spectroscopy. [Os(tmphen)3]3+ stability is compared with [Ru(tmphen)3]3+ in the same pH 7 environment. The properties of Os(III) and Ru(III) complexes were investigated for use as the oxidant in a PFET system. Studies of photophysical and electrochemical properties, the stability of the Os(III) and Ru(III) complexes, and analytical application in PFET detection of oxidizable analytes are presented. The spectroscopic properties of the complexes were not very advantageous, but careful control of the detection system and reaction conditions enabled sensitive detection of the analytes. The method was fully validated and the optimized system was capable of detecting dopamine and acetaminophen at about 30.2 µg L-1 and 33.5 µg L-1, respectively. The limit of detection (LOD) was 1.5 µg L-1 for acetaminophen and 4.3 µg L-1 for dopamine. The accuracy and precision were within bioanalytical method validation limits (90.9 to 101.5 % and RSD < 12.0 %, respectively). Typical analysis time was less than 15 minutes. Two Fenton-based flow-injection chemiluminescence (CL) methods were developed and validated for the determination of naproxen. Under the optimal experimental conditions the proposed methods exhibited advantages in a larger linear range from 2,760 ng mL-1 to 207,000 ng mL-1 for the first CL method and 41.4 ng mL-1 to 700.0 ng mL-1 for the second CL method. The LOD was 13.8 ng mL-1 for naproxen. The CL mechanisms for the system, H2O2-FeIIEDTA-naproxen was further studied by batch experiments, chemiluminescence spectroscopy, fluorometry, high pressure liquid chromatography (HPLC) and Fourier transform infrared spectroscopy (FTIR). The effects of various interferences commonly found in biological and wastewater systems on the chemiluminescence intensity were also investigated. We used these methods to determine NSAIDs in commercial pharmaceutical formulations. Another application of these method was for detecting NSAIDs in biological samples. A 2x-1-Dimensional Solid Phase Extraction (2x-1D SPE) method was developed for determination of acetaminophen and naproxen in urine. This method uses both the methanol concentration and the pH advantageously to preferentially isolate analytes of interest from complex sample matrix. These methods were fully validated and had sufficient sensitivity (limit of quantification: acetaminophen; 40.41 mg L-1 - 360.0 mg L-1 and naproxen; 23.03 mg L-1 - 214.8 mg L-1) for biological matrices and applications.
    ADA compliance
    For Americans with Disabilities Act (ADA) accommodation, including help with reading this content, please contact scholarshare@temple.edu
    Collections
    Theses and Dissertations

    entitlement

     
    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Temple University Libraries | 1900 N. 13th Street | Philadelphia, PA 19122
    (215) 204-8212 | scholarshare@temple.edu
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.