dc.description.abstractPiezoelectric and high speed rotary instrumentation have proven to be viable methods of preparing osteotomies during lateral sinus wall surgery. Piezoelectric units have been suggested to have superior access and control as well as the ability to discern between soft and hard tissue. The major disadvantage of the piezoelectric technology is the reduced speed at which osteotomies are prepared. The purpose of this study was to evaluate the difference in operator perception, speed and membrane damage between the two modalities. Seven different operators prepared 4 osteotomies in 2 mm thick polyurethane sheets backed by 0.2 mm thick plastic wrap. The preparation speed and incidence of membrane damage were recorded after each osteotomy. The operator perception of each modality was recorded at the end of the preparations. Several questions were asked to evaluate the accuracy, visibility, vibration, comfort and ease of use of both modalities. Results showed that rotary instrumentation was 160% faster than piezo (p<0.001), but resulted in 370% more damage and 130% more perforations (p<0.01). Surveys of operator preference showed piezo units with higher scores for accuracy and visibility (p<0.05). This study showed that in vitro a piezo unit compared to a rotary unit results in less membrane perforation and damage, higher perception of accuracy and visibility, but longer osteotomy preparation time.
dc.format.extent29 pages
dc.language.isoeng
dc.publisherTemple University. Libraries
dc.relation.ispartofTheses and Dissertations
dc.rightsIN COPYRIGHT- This Rights Statement can be used for an Item that is in copyright. Using this statement implies that the organization making this Item available has determined that the Item is in copyright and either is the rights-holder, has obtained permission from the rights-holder(s) to make their Work(s) available, or makes the Item available under an exception or limitation to copyright (including Fair Use) that entitles it to make the Item available.
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectDentistry
dc.subjectBur
dc.subjectOsteotomy
dc.subjectPerforation
dc.subjectPiezo
dc.subjectSchneiderian
dc.subjectSinus
dc.titleAN IN VITRO COMPARISON OF PIEZOELECTRIC AND ROTARY OSTEOTOMIES DURING LATERAL SINUS WALL SURGERY
dc.typeText
dc.type.genreThesis/Dissertation
dc.contributor.committeememberRams, Thomas E.
dc.contributor.committeememberBrown-Joseph, Belinda
dc.contributor.committeememberBoston, Daniel
dc.description.departmentOral Biology
dc.relation.doihttp://dx.doi.org/10.34944/dspace/1997
dc.ada.noteFor Americans with Disabilities Act (ADA) accommodation, including help with reading this content, please contact scholarshare@temple.edu
dc.description.degreeM.S.
refterms.dateFOA2020-10-27T15:28:08Z


Files in this item

Thumbnail
Name:
Nicolucci_temple_0225M_10785.pdf
Size:
808.8Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record