Loading...
Thumbnail Image
Item

Methodology for detecting trace amounts of microchimeric DNA from peripheral murine white blood cells by real-time PCR

Artlett, CM
Dito, CG
Christner, PJ
Citations
Altmetric:
Genre
Journal Article
Date
2003-12-01
Advisor
Committee member
Group
Department
Subject
Permanent link to this record
Research Projects
Organizational Units
Journal Issue
DOI
10.1251/bpo51
Abstract
Real-time PCR methodology can successfully quantitate microchimeric cell populations at a concentration of 100 microchimeric cells/100,000 host cells; however, it has not been successful in quantitating DNA from trace numbers of microchimeric white blood cells which we reported are present in murine peripheral blood at a concentration as low as 2/100,000 host cells. We report methodology using primers for a portion of the H2-kb murine histocompatibility sequence, specific for the C57BL/6J mouse. When these primers were used in the presence of 11,000 μM primer, a 20-fold increase in the median manufacturer's recommended concentration, the assay could be optimized to detect 34 pg of C57BL/6J DNA in a background of 2.5 μg of carrier BALB/cJ DNA (1/100,000). These conditions resulted in a detection limit half as sensitive as that found when no carrier DNA was present.