Loading...
ACCURACY OF SURVEYED CROWN DESIGN DUPLICATION WITH CAD/CAM TECHNOLOGY COMPARED WITH CONVENTIONAL METHODS IN PARTIALLY EDENTULOUS KENNEDY CLASS III ARCH FORM
Ghassemi, Ghazal Ghassemi
Ghassemi, Ghazal Ghassemi
Citations
Altmetric:
Genre
Thesis/Dissertation
Date
2024-08
Advisor
Committee member
Group
Department
Oral Biology
Subject
Permanent link to this record
Collections
Research Projects
Organizational Units
Journal Issue
DOI
http://dx.doi.org/10.34944/dspace/10880
Abstract
Fabrication of a surveyed crown under an existing RPD requires designing a crown pattern that duplicates the coronal anatomy of the existing tooth including all undercut and non-undercut areas and occlusal rest seats. The aim of this study was to evaluate the accuracy of surveyed crown design duplication with CAD/CAM technology compared with the conventional methods in partially edentulous Kennedy class III arch form in an in vitro study. A maxillary dentiform with Kennedy Class III partial edentulism was used (missing teeth #4,13,14). Tooth #3 was prepared, and a PFM surveyed crown was fabricated and cemented with the appropriate contours to receive an Akers-type clasp: distal rest, circumferential direct retainer and reciprocal arm. A cast chrome-cobalt RPD framework was fabricated using conventional methods. The existing PFM crown was replaced by the surveyed study crowns for comparison. 10 PFM crowns were fabricated using a conventional method and 10 Zirconia crowns were fabricated using CAD/CAM method. The vertical position of HOC and crown thicknesses were measured in six spots (MB, B, DB, MP, P , DP) on each crown. The results of the present study indicated that CAD/CAM technology provided superior accuracy of surveyed crown design duplication compared to the conventional method. In terms of HOC vertical position, CAD/CAM crowns were significantly more accurate than the conventional crowns on the buccal side of the crown. On average, the HOC on the conventional crowns was 0.83  0.37, 1.27  0.64, and 1.23  0.48 mm higher than the control crown on the MB, B, and DB sites, respectively. On the lingual side, there was no significant difference between the two methods. In terms of the crown thickness, both methods yielded relatively similar results. The largest difference in crown thickness between test and control crowns was found in the DB site of the conventional group where the crowns were significantly thinner than the control. 
Description
Citation
Citation to related work
Has part
ADA compliance
For Americans with Disabilities Act (ADA) accommodation, including help with reading this content, please contact scholarshare@temple.edu